Power Cable

Why Choose Us

We have a variety of specifications for power cables, which can be customized according to needs.

Strict material selection - Good raw materials are the guarantee of good products

We have conducted multiple experiments to select the most suitable raw materials for each cable, which are from national and international first tier brands and are genuine and cost-effective!

On demand customization - can be produced according to different specifications and models

The customer manager assigns a dedicated quotation to fully meet the production needs of product orders,

The majority of our company's products have a production cycle of 5-7 days.

Professional team

Our team includes pre-sales, after-sales service, designers, craftsmen, and inspectors. The team is well-established and has over 10 years of experience in mobile cable design and generation.

Product consistency

Our company guarantees the stability and consistency of each batch of cables for long-term customers with our strength!

 

 

First 123456 Last 1/6

Complete Power Cable Range

Different power cable types require different conductor structures, insulation grades, armouring solutions and safety ratings. Buyers should define voltage rating, installation environment and fire‑safety requirements before selecting conductor and cross‑section.

Low‑Voltage Power Cable (0.6/1kV)

We supply low‑voltage power cables (LV mains cable, NYY/NAYY equivalent) for building distribution, industrial workshop power supply, machinery power feed, commercial facilities and general fixed installation.

Common conductor options: Solid copper, stranded copper, aluminum, aluminum‑alloy (AA‑8000) (Class1 / Class2 / Class5 flexible)

Common core configurations: 1‑core, 2‑core, 3‑core, 4‑core, 5‑core, 3+1 core, 3+2 core,4+1 core

Insulation & sheath material options: XLPE, PVC, EPR, LSZH low‑smoke zero‑halogen (LS0H / HFFR)

Armouring options: Unarmoured, SWA steel‑wire armoured, STA steel‑tape armoured, AWA aluminum‑wire armoured

Depending on construction, LV power cables are suitable for:

Indoor cable tray / conduit installation

Direct underground burial

Wall & building wiring

Industrial equipment power supply

Commercial building distribution

Emergency & fire‑safety circuits

Solar‑power station DC‑AC connection

Off‑shore platform auxiliary circuits

Cross‑section range varies by conductor and core structure. Final drum (reel) length, core count and armouring capability must be confirmed against your exact specification.

Medium‑Voltage Power Cable (6kV‑35kV)

Medium‑voltage XLPE power cables (MV distribution cable, 11kV/33kV SWA cable) are used for power transmission between substations, renewable‑energy farm grid‑connection, mining and heavy‑industry projects.

Common conductor options: Copper, Aluminum

Typical supply capability for selected MV power cables:

Item Typical Supply
Product Medium‑voltage XLPE insulated power cable (11kV / 33kV MV distribution cable)
Rated Voltage 6/10kV, 8.7/15kV,12/20kV,18/30kV,26/35kV
Cross‑section 16 mm²‑1200 mm²
Core structure Single‑core / Three‑core
Armouring SWA / STA / AWA / Non‑armoured
Sheath PVC, PE, LSZH (LS0H), water‑blocking sheath
Processing Custom drum/reel‑length cutting, cable printing
Special features Water‑blocking, anti‑termite, UV‑resistant upon request

Actual capability varies by conductor material, armouring structure, fire‑performance grade and testing requirements.

LSZH / Flame‑Retardant / Fire‑Resistant Power Cable

We also supply flame‑retardant (ZR), fire‑resistant (NH, CI Circuit Integrity), low‑smoke zero‑halogen (LSZH / LS0H / HFFR) power cables for public‑safety‑critical projects.

Options include:

ZA/ZB/ZC grade flame‑retardant performance

Fire‑resistant circuit‑integrity construction (CI cable)

Low‑smoke density & zero‑halogen emission

Custom fire‑safety test requirements per project specification

Black / custom outer‑sheath colour

These cables are widely used for tunnels, metro stations, high‑rise buildings, hospitals, underground car‑parks and public transport infrastructure.

Aluminum‑Alloy Power Cable

Aluminum‑alloy power cables (AA‑8000 alloy cable) provide cost‑effective lightweight power‑distribution solutions for urban grid upgrade, commercial real‑estate and long‑distance distribution projects.

Common models: YJHLV, YJHLV22, YJHLV82

Key advantages: improved mechanical bending performance, good corrosion resistance, lower total project cost compared with copper cables for certain distribution scenarios.

Overhead Insulated Aerial Power Cable

Overhead insulated cables, also known as ABC (Aerial Bundled Cable), are applied for urban overhead power‑grid reconstruction, rural power‑supply renovation. Avoid short‑circuit risk caused by tree‑branch contact.

Conductor: Copper / Aluminum‑alloy Voltage grade: 0.6/1kV ~ 10kV Installation: Aerial pole‑mounted installation.

Power Cable Construction Guide

Buyers shall select cable construction balancing conductivity, mechanical strength, corrosion resistance, fire‑safety, installation condition, short‑circuit withstand capacity and total project cost.

Cable Type Main Construction Typical Grades Overseas Common Designations Main Characteristics Typical Applications
Copper Conductor LV Cable Copper + XLPE/PVC insulation + sheath + optional armour YJV, YJV22 NYY, NYCY, NAYY, SWA Cable, 600/1000V Mains Cable Excellent conductivity, stable mechanical performance, wide application range Building wiring, industrial power distribution, equipment power feed
Aluminum‑Alloy Cable Aluminum‑alloy conductor + XLPE insulation + sheath + optional armour YJHLV, YJHLV22 AA-8000 Alloy Cable, Aluminum Alloy XLPE Distribution Cable Light‑weight, cost‑effective, good bending property Urban grid reconstruction, long‑distance distribution
Medium‑Voltage XLPE Cable Cu/Al conductor + inner screen + XLPE insulation + outer screen + sheath + armour YJV‑MV, YJLV‑MV MV XLPE Cable, 11kV /33kV SWA Cable, EPR Medium Voltage Cable High‑voltage withstand capacity, stable dielectric performance Substation connection, wind‑solar farm grid‑tie, heavy‑industry
LSZH Low‑Smoke Zero‑Halogen Cable Cu/Al conductor + LSZH insulation & sheath WDZ‑YJY, WDZN‑YJY LS0H Cable, HFFR Cable, Low Smoke Zero Halogen Cable Low smoke, no toxic halogen gas when burning Tunnel, metro, high‑rise building, public facilities
Fire‑Resistant Cable Copper conductor + fire‑resistant mica‑tape layer + insulation + sheath NH‑YJV, NH‑YJY CI Circuit Integrity Cable, Fire Survival Cable Maintain circuit integrity under fire condition Emergency lighting, fire‑fighting equipment power supply
Overhead Insulated Cable Aluminum / copper conductor + weather‑resistant insulating layer JKLYJ, JKYJ ABC Aerial Bundled Cable, Overhead Insulated Line UV‑resistant, aerial installation Urban & rural overhead power‑grid

How to Select the Right Power Cable

Choose Copper Conductor When Reliability & Compact Installation Matter

Copper‑conductor cables (NYY/NYCY equivalent) feature high conductivity, stable mechanical strength, smaller voltage drop, suitable for high‑load equipment, short‑distance industrial installations and high‑reliability critical circuits. Typical uses: industrial workshops, commercial building main power supply, fire‑safety circuits, equipment internal power feed.

Choose Aluminum‑Alloy Cable for Cost‑Sensitive Long‑Distance Distribution

Aluminum‑alloy cables (AA‑8000 alloy cable) deliver obvious cost advantages for long‑distance power‑distribution. It is widely used for urban grid transformation, large residential‑district power supply. Please calculate voltage drop and short‑circuit capacity in advance.

Choose Armoured Cable for Direct‑Burial / Mechanical‑Risk Environment

Select SWA/STA armoured construction (SWA armoured cable) when cables are directly buried underground, passing through road zones or exposed to mechanical‑damage risk. Armour provides mechanical protection against external impact. For corrosive soil environment, additional anti‑corrosion sheath shall be specified.

Choose LSZH / Fire‑Resistant Cable for Public‑Safety‑Critical Projects

For tunnels, metro, high‑rise buildings, hospitals and underground public spaces, specify LSZH (LS0H / HFFR) flame‑retardant or fire‑resistant CI circuit integrity cables to avoid toxic smoke diffusion during fire accident. Confirm required flame‑retardant grade (ZA/ZB/ZC) and fire‑survival time.

Choose Medium‑Voltage XLPE Cable for Substation & Renewable‑Energy Grid‑Connection

MV XLPE cables (11kV/33kV distribution cable) are the mainstream solution for power transmission between substations and wind‑photovoltaic power‑station grid‑connection. Confirm rated voltage, cross‑section, single‑core / three‑core structure and short‑circuit withstand requirement.

Understanding Key Cable Parameters

Correct parameter selection is equally important as choosing cable model.

Conductor Class

Class1: Solid single‑wire conductor, for fixed installation

Class2: Stranded compacted conductor, widely used for power‑cable fixed installation

Class5 / Class6: Flexible stranded conductor, for moving‑equipment connections (flexible cable)

Voltage Rating

0.6/1kV for most low‑voltage distribution (600/1000V mains); 6/10kV‑26/35kV for medium‑voltage transmission (11kV, 33kV MV). Voltage rating must match system operating voltage.

Armouring

SWA: Steel‑wire armoured, for underground direct‑burial, anti‑impact (Steel Wire Armour)

STA: Steel‑tape armoured, anti‑crush (Steel Tape Armour)

AWA: Aluminum‑wire armoured, anti‑magnetic eddy‑current for single‑core MV cables (Aluminium Wire Armour)

Unarmoured: For cable‑tray / conduit indoor installation without mechanical‑damage risk

Important: Not every armouring type is applicable for single‑core medium‑voltage cables; magnetic‑armour selection rules must be followed.

Power Cable Standards

We can produce power cables complying with widely‑accepted IEC, GB, BS, VDE international standards per project requirements.

Standard Typical Product Scope
IEC 60502‑1 Low‑voltage extruded insulation power cables (0.6/1kV, NYY type)
IEC 60502‑2 Medium‑voltage extruded insulation power cables (6kV‑35kV,11kV/33kV)
GB/T 12706 Chinese national standard for XLPE insulated power cables
IEC 60331 Fire‑resistant cable fire‑survival performance test (CI circuit integrity)
IEC 60754 Low‑smoke zero‑halogen (LS0H) test standard
IEC 60228 Cable conductor specification
BS 5467 / BS 6622 British standard SWA armoured power cables

Standard number alone cannot fully define cable purchase specification. Always confirm together with conductor, cross‑section, core count, armouring, fire‑safety grade and installation environment.

Sheath & Special Performance Options

Subject to cable type, available sheath and special‑performance options include:

Ordinary PVC sheath

PE polyethylene sheath

LSZH low‑smoke zero‑halogen sheath (LS0H / HFFR)

Anti‑termite sheath

Water‑blocking structure (longitudinal / radial water‑blocking)

UV‑resistant sheath for outdoor / aerial exposure (ABC cable application)

Custom outer‑sheath colour

Custom cable surface printing (cable model, voltage, meter marking, customer logo)

For underground, coastal, chemical‑plant corrosive environment, buyers shall clearly specify corrosion‑resistance, water‑blocking and anti‑biological‑damage requirements.

Power Cable Customization & Processing

Shaanxi Jinshenghong Cable Co., Ltd. supports industrial and EPC customers requiring finished‑to‑project‑requirement power cables.

Length Cutting

Produce cables to required drum/reel length, avoid on‑site waste. Standard wooden / steel drum (reel) packing.

Cable Printing & Marking

Custom print model, voltage, meter mark, customer logo on outer sheath.

Special‑Structure Customization

Water‑blocking, anti‑termite, UV‑resistant, flame‑retardant and fire‑resistant (CI circuit integrity) customized construction.

Technical Support

Assist in cable‑type selection, voltage‑drop reference calculation, parameter review for project bidding documents.

Power Cable Quality Inspection

B2B power‑cable procurement must rely on measurable testing indicators instead of visual appearance only.

Depending on purchase specification, inspection scope includes:

Material Identification

Conductor material verification, batch traceability, insulation & sheath material component check.

Dimensional Inspection

Conductor cross‑section, insulation thickness, sheath thickness, outer‑diameter tolerance, drum/reel length verification.

Electrical Performance Test

Conductor DC resistance, partial‑discharge test, high‑voltage withstand test, insulation resistance, short‑circuit withstand capacity verification.

Mechanical & Environmental Test

Tensile strength & elongation for insulation / sheath, ageing test, bending test.

Fire‑Safety Performance Inspection (when specified)

Flame‑retardant test, fire‑survival integrity test, smoke‑density and halogen‑gas emission test for LS0H / LSZH cables.

Additional Inspection

Water‑blocking performance test, anti‑termite test, third‑party witness inspection, type‑test report (TTR) provision.

Material Documentation

Documentation can be issued per contract requirement. Typical documentation includes: Material Test Certificate (MTC), EN 10204 3.1 certificate (where applicable), conductor resistance report, insulation‑thickness test report, type‑test report (TTR), Certificate of Origin, packing list, commercial invoice, third‑party inspection report upon request.

Customers requiring SGS or other independent inspection agency services shall state requirements before production.

Power Cable by Industry

Power Utility & Grid Projects

Recommended products: Medium‑voltage XLPE power cable (11kV/33kV distribution cable), aluminum‑alloy distribution cable (AA‑8000), overhead insulated aerial cable (ABC Cable). Key purchasing factors: conductor specification, voltage grade, short‑circuit withstand, standard compliance, batch traceability, type‑test documentation (TTR).

Building & Construction

Products: 0.6/1kV copper LV power cable (NYY equivalent), armoured buried SWA cable, LSZH (LS0H) flame‑retardant cable, fire‑resistant CI emergency‑circuit cable. Application: High‑rise buildings, commercial complexes, residential communities, underground parking lots.

Renewable‑Energy: Wind & Solar Power Station

Products: MV grid‑connection power cable, DC‑AC power‑feed cable, UV‑resistant outdoor cable, water‑blocking underground cable. Common requirements: anti‑UV, water‑blocking, wide‑temperature‑range performance.

Industrial & Manufacturing Plants

Products: Copper LV armoured SWA power cable, medium‑voltage factory‑incoming cable, flame‑retardant cable. Application: Production workshop power supply, heavy‑equipment power feed, mining industrial facilities.

Tunnel, Metro & Public‑Transport Infrastructure

Products: LSZH low‑smoke zero‑halogen (LS0H / HFFR) cable, fire‑resistant CI power cable. Key focus: smoke‑toxicity index, flame‑retardant grade, fire‑survival circuit‑integrity performance.

Marine & Off‑Shore Auxiliary Circuit

Products: Special anti‑corrosion power cable, water‑resistant sheath cable. Note: For marine‑class certified cables, customers shall specify marine‑certification requirements before quotation; general industrial cables cannot automatically satisfy marine‑standard requirements.

Why Choose Shaanxi Jinshenghong Cable Co., Ltd. for Power Cable Supply?

Shaanxi Jinshenghong Cable Co., Ltd. is a professional power cable manufacturer and supplier serving distributors, electrical contractors, EPC companies, equipment manufacturers and project buyers.

Our manufacturing & logistics network includes: 5 Manufacturing Centers Supporting cable product manufacturing.

18 Production Lines Covering copper, aluminum and power‑cable serial‑product production.

10 Warehouses Support stock management, order consolidation and global export delivery.

588 Employees Covering production, quality‑control, technical engineering, international‑trade and logistics teams.

Multi‑Product Consolidated Procurement

Customers can combine different cable orders for consolidated shipment.

Cable‑Selection Technical Support

Our engineering team assists buyers to compare conductor options, voltage grades, armouring and fire‑safety solutions rather than only quoting based on simple model names.

OEM & ODM Capability

Custom drum/reel‑length, sheath printing, special‑performance cable construction and customized packing solutions.

Complete Quality Documentation

Full‑set test certificates and inspection documents (MTC, TTR, 3.1 cert) supplied per purchase specification.

Third‑Party Witness Inspection

Independent third‑party inspection available upon customer’s project requirement.

Export‑Qualified Drum Packaging

Wooden / steel export drums (reels), moisture‑proof wrapping, drum marking, anti‑collision protection for ocean‑going transport.

Export Packaging

Power cables are delivered on wooden or steel export drums (reels); proper packaging prevents sheath scratch, moisture ingress and mechanical damage during long‑distance ocean transport.

LV / MV power‑cable drums (reels) Moisture‑proof inner wrapping, drum‑end protection, metal‑steel‑band fastening, clear drum marking including project mark, cable model, total length, net/gross weight. Wooden or steel export drums according to cable weight.

Special shipping or packaging requirements must be stated in your RFQ inquiry.

How to Send a Complete Power Cable RFQ

Complete technical inquiry helps our sales & engineering team provide fast, accurate quotation and avoid specification deviation.

Please provide:

Cable Type LV / MV power cable, armoured (SWA/STA/AWA) / non‑armoured, LSZH(LS0H) / fire‑resistant(CI) / ABC aerial cable etc.

Conductor Material & Class Copper / Aluminum / Aluminum‑alloy (AA‑8000); IEC 60228 Class1 / Class2 / Class5 flexible

Core Configuration & Cross‑Section Example: 3×120+1×70 mm²; 1×300 mm² three‑core etc.

Rated Voltage 0.6/1kV, 8.7/15kV, 12/20kV, 26/35kV etc.

Insulation / Sheath / Armouring XLPE / PVC / LSZH(LS0H); SWA / STA / AWA / unarmoured

Applicable Standard IEC 60502‑1 / IEC 60502‑2 / GB/T 12706 / BS / VDE standard etc.

Quantity & Drum/reel‑length requirement Total meters / kilometers; required per‑drum length

Special Performance Requirement Flame‑retardant grade, fire‑resistant (CI circuit integrity), water‑blocking, anti‑termite, UV‑resistant, sheath printing & logo requirement

Inspection & Document Requirement MTC, EN 10204 3.1, type‑test report (TTR), third‑party witness inspection

Application & Installation Condition Building distribution / underground direct‑burial / tunnel / solar‑wind farm / overhead aerial ABC; corrosive‑soil / coastal‑salt‑spray environment

Delivery Destination & Trade Term Destination country / seaport; FOB / CIF etc.

Material selection and production of power cables

 

Good materials and technology contribute to the success of good cables

-01

The selection of high-quality conductor material (oxygen free copper) for power cables has the following characteristics:

High conductivity: Oxygen free copper has a high conductivity and low resistivity, which can ensure the stability and reliability of current transmission.

Good mechanical properties: Oxygen free copper has good plasticity and ductility, making it easy to process into various specifications of cable cores and cables.

Corrosion and oxidation resistance: Oxygen free copper is not easily corroded and oxidized, ensuring long-term stable operation of cables.

Good welding performance: The welding performance of oxygen free copper is excellent, which can meet the needs of various cable connections and installations.

-1

Choose high-quality insulation materials for power cables based on different cables

  Common cable insulation materials include polyethylene (PE), cross-linked polyethylene (XLPE), polyvinyl chloride (PVC), fluoroplastics, etc.

  Polyethylene and cross-linked polyethylene have good electrical properties, heat resistance, and chemical stability, and are widely used for insulation of low-voltage and medium high voltage cables; Polyvinyl chloride has good electrical and processing properties, but has low heat resistance and is prone to aging.

  It is commonly used for insulation in general household appliances and building electrical systems; Fluoroplastics have excellent heat resistance and chemical corrosion resistance, and are widely used for cable insulation in high temperature and chemical corrosion environments.

-001

Precision equipment and advanced technology are necessary conditions for producing power cables

Drawing: The drawing process is to draw the raw material of the conductor into a single wire with the desired cross-sectional shape and size through a drawing machine. According to different needs, it can be done through single wire drawing and twisted drawing methods.

Twisting: The twisting process involves interweaving multiple single wires in a specified direction to form a wire core that meets the flexibility requirements. This step can improve the flexibility and overall integrity of wires and cables.

Wrapping: The wrapping process involves passing the pre made wire core through an extruder, allowing the insulation layer to wrap around the conductive wire core. According to different performance requirements for wires and cables, specialized equipment can be used to wrap different materials on the outside of the conductor, such as rubber, plastic, lead, aluminum, etc.

 
FAQ
 

Purchasing cables, many customers are concerned about the following issues

 

 

1

Q:What power‑cable types can you supply?

A:We supply low‑voltage (0.6/1kV, NYY type) and medium‑voltage (6‑35kV,11kV/33kV) power cables: copper‑conductor, aluminum‑alloy (AA‑8000) conductor, SWA armoured /unarmoured, LSZH (LS0H) low‑smoke zero‑halogen, flame‑retardant, fire‑resistant CI and overhead insulated ABC aerial power cables.

 

2

Q:What is the difference between armoured and unarmoured power cable?

A:Armoured cables adopt steel‑tape /steel‑wire armour layer (SWA/STA) to resist external mechanical impact, suitable for direct‑burial underground. Unarmoured cables are for indoor cable‑tray /conduit installation without mechanical‑damage risk. Single‑core medium‑voltage cables have special‑armour selection rules to avoid eddy‑current heating.

3

Q:Copper vs aluminum‑alloy power cable, how to choose?

A:Copper cable (NYY/NYCY) has higher conductivity, smaller voltage drop, compact outer‑diameter, higher total cost. Aluminum‑alloy cable (AA‑8000) reduces project material cost, lighter weight, suitable for long‑distance distribution grid reconstruction. Please calculate voltage drop and short‑circuit capacity before selecting aluminum‑alloy cables.

4

Q:When should I choose LSZH low‑smoke zero‑halogen power cable?

A:LSZH (LS0H / HFFR) cables produce low‑smoke and non‑toxic‑halogen gas under burning. It is mandatory for tunnels, metro stations, high‑rise public‑buildings and underground‑public‑space projects. Ordinary PVC cables cannot replace LS0H for these safety‑critical scenarios.

5

Q:Can you provide fire‑resistant power‑cable with circuit‑integrity performance?

A:Yes. We supply fire‑resistant CI circuit integrity power cables built with mica‑tape fire‑barrier layer. You shall specify required fire‑survival time and corresponding test standard for your project.

6

Q:Can you customize cable drum/reel length and sheath printing?

A:Yes. We can produce cables to your requested drum/reel‑cut length, and print cable model, voltage, meter‑mark and customer logo on outer sheath.

7

Q:What international standards can your power‑cables comply with?

A:Our cables can be manufactured complying with IEC 60502‑1, IEC 60502‑2, GB/T 12706, BS 5467, VDE and other international standards subject to cable construction.

 

 

 

Shaanxi Jinshenghong Cable Co., Ltd. is well-known as one of the leading power cable manufacturers and suppliers in China. If you're going to wholesale cheap power cable for sale, welcome to get free sample from our factory. All customized products are with high quality and low price.

multi core power cable, order power cable, Steel Wire Armoured Cable