Shaanxi Jinshenghong Cable Co., Ltd. is one of the most reliable manufacturers and suppliers of vde h07rn-f rubber cable in China. Please feel free to wholesale high quality customized products at low price from our factory. For free sample and cheap products, contact us now.
Products Description

H07RN-F Rubber Cable | EPR Insulation CR Sheath, Weatherproof, Oil Resistant, Heavy Duty Rubber Cable, VDE / UL / SAA Versions for Industrial & Construction Temporary Power
Shaanxi Jinshenghong Cable Co., Ltd. supplies H07RN-F Rubber Cable, also known as VDE H07RN-F rubber flexible cable, widely used for portable electrical equipment, construction temporary power, generator connection, water pump, outdoor lighting and heavy-duty mobile power circuits.
We develop three mainstream regional versions to match different market certification requirements:
German VDE Version: Complies with VDE 0282, HD 22.4, 450/750V, the standard H07RN-F specification, widely used in EU construction and equipment projects, LAPP H07RN-F equivalent type
US UL Version: UL rubber flexible cable equivalent, AWG conductor sizing, suitable for North America portable power equipment
Australian SAA Version: AS/NZS 5000.1, SAA certified, for Australia and New Zealand outdoor temporary power market
H07RN-F adopts EPR ethylene propylene rubber insulation and chloroprene rubber (CR) outer sheath. It features excellent weather resistance, ozone resistance, moderate oil resistance and good flexibility, suitable for frequent moving, twisting and outdoor exposed installation.
We support B2B project sourcing, custom core counts, custom cross-section / AWG size, custom marking, full set test certificates and customized export packaging.
Customers can request quotations for standard VDE H07RN-F, UL equivalent rubber cable, AS/NZS 5000.1 SAA rubber cable, different core sizes such as H07RN-F Cable 2.5mm 3 Core, according to project specification.
What Is H07RN-F Rubber Cable?
H07RN-F rubber cable is a heavy-duty flexible rubber power cable defined by European harmonized standard HD 22.4 and VDE 0282. The name H07RN-F cable meaning has clear definition:
H = Harmonized European cable standard
07 = Rated voltage 450/750V
R = Rubber insulation
N = Neoprene (CR) rubber sheath
F = Flexible fine-stranded copper conductor
Conductor is fine stranded oxygen-free copper; US UL version uses AWG gauge conductors, Australia SAA version meets AS/NZS stranding requirements. Common core specifications: 1C,2C,3C,4C,5C;
Metric cross-section: 1mm²,1.5mm²,2.5mm²,4mm²,6mm²,10mm²,16mm² (VDE / SAA)
AWG sizes: 18AWG,16AWG,14AWG,12AWG (US equivalent version)
One of the most popular specs is H07RN-F Cable 2.5mm 3 Core, widely used for power tools and small mobile machinery.
This cable is dedicated for mobile, temporary power supply, not suitable for fixed permanent wiring indoors without mechanical protection. Typical environments: construction site, portable generator, electric pump, welding equipment, outdoor stage lighting, heavy duty extension leads.
Key Material Advantages
| Property | Engineering Benefit |
|---|---|
| EPR Rubber Insulation + CR Neoprene Sheath | Outstanding flexibility, ozone and weather resistance, suitable for outdoor exposure |
| Fine Stranded Flexible Copper Conductor | Easy to bend, withstand frequent movement and twisting |
| Regional Certified Versions | VDE (DE), UL equivalent (US), AS/NZS 5000.1 SAA (AU) to meet local electrical approval |
| Good Oil & Abrasion Resistance | Resist light machine oil, abrasion from dragging on construction ground |
| Wide Application Temperature Range | -25℃ ~ +60℃ for normal continuous operation |
| Stable Current Carrying Capacity | Clear H07RN-F Cable current Carrying Capacity data for site power calculation |
| Standardized Size Range | Complete Vde h07rn f rubber cable size options for different load demands |
Engineering Note: Installation shall strictly comply with local wiring codes: IEC 60364, NFPA 70 (US), AS/NZS 3000 (Australia), VDE 0100 (Germany). The current carrying capacity must be selected according to ambient temperature, grouping and laying method to avoid overheating.
H07RN-F Rubber Cable Product Specifications
Below data is procurement reference for H07RN-F and equivalent rubber flexible cables. Real available core counts and cross-sections depend on production capacity, MOQ and certification scope.
| Product Form | Cross‑section / AWG Reference | Supply Condition |
|---|---|---|
| VDE Standard H07RN-F (German Version) | 1mm² ~ 16mm², 1C ~ 5C | VDE 0282, HD22.4, 450/750V, black CR sheath, LAPP H07RN-F equivalent |
| UL Equivalent Rubber Cable (US Version) | 18AWG ~ 12AWG, 1C ~ 5C | UL listed rubber flexible cable, AWG marking, compliant with NFPA70 |
| SAA AS/NZS 5000.1 Rubber Cable (AU Version) | 1mm² ~ 16mm², 1C ~ 5C | SAA certified, meets AS/NZS 3000 wiring rule |
| H07RN-F Cable 2.5mm 3 Core | 2.5mm², 3 core | Hot selling spec for portable power tools and extension cords |
| Custom Rubber Cable | Special core count / special cross-section / special color | Subject to technical feasibility & minimum order |
| Packing Form | 100m/200m/500m/roll, wooden drum packing | Factory standard packing or customized export packing |
Cross‑section and core options listed are typical industry references, not guaranteed stock. Final availability and certification scope must be confirmed during quotation.
Common Supply Requirements
| Parameter | Available Procurement Options |
|---|---|
| Product Grade | VDE H07RN-F / UL equivalent rubber cable / AS/NZS5000.1 SAA rubber cable |
| Primary Standard | VDE 0282, HD22.4, IEC 60245, UL rubber cable standard, AS/NZS 5000.1, CE RoHS |
| Local Wiring Code | VDE 0100 (DE), NFPA 70 (US), AS/NZS 3000 (AU), IEC 60364, as specified |
| Rated Voltage | 450/750V |
| Temperature Class | -25℃ ~ +60℃ |
| Conductor Material | Fine stranded oxygen-free copper; AWG sizing for UL version |
| Core Count | 1C,2C,3C,4C,5C; popular H07RN-F Cable 2.5mm 3 Core |
| Sheath Color | Black standard; other colors optional |
| Length | Standard reel length or custom cut‑to‑length |
| Dimensional Tolerance | Follow corresponding product standard or buyer drawing |
| Product Marking | Metric marking / AWG marking, continuous meter marking, batch number traceability |
| Inspection Certificate | EN10204‑3.1, UL test report, SAA test report, current carrying capacity test report, CE RoHS document upon agreement |
For critical construction and portable power projects, buyers shall specify certification standard (VDE / UL / SAA), core count, cross-section/AWG before placing order. You can check the H07RN-F Datasheet for full technical parameters.
H07RN-F Rubber Cable Construction Parameters
| Component | Description |
|---|---|
| Conductor | Fine stranded flexible oxygen-free copper, meets IEC 60228 Class 5 |
| Insulation | EPR ethylene propylene rubber insulation, color coded for each core |
| Inner Filling | Rubber filler to keep round cable structure |
| Outer Sheath | CR chloroprene neoprene rubber sheath, abrasion, ozone and weather resistant |
| Rated Voltage | 450/750V |
| Max Continuous Operating Temperature | +60℃ |
| Test Voltage | AC 2500V routine withstand test |
Construction compliance shall refer to VDE 0282, HD22.4, UL rubber standard or AS/NZS 5000.1, based on buyer market requirement.
Electrical & Physical Properties
| Property | Typical Reference Value |
|---|---|
| Rated Voltage | 450/750V |
| Maximum Conductor Operating Temperature | +60℃ |
| Minimum Installation Ambient Temperature | -25℃ |
| Minimum Bending Radius | ≥6 × overall cable diameter |
| Current Carrying Capacity | Follow standard H07RN-F Cable current Carrying Capacity table, related to cross-section and ambient temperature |
| Environmental Resistance | Ozone, weather, sunlight, light oil resistance |
| Flame Retardant Characteristic | Self-extinguishing rubber compound as per VDE flame test |
Values for preliminary engineering reference. Actual current carrying capacity must be reduced for high ambient temperature, bundled laying or long distance circuits.
VDE H07RN-F vs UL Equivalent vs AS/NZS5000.1 Rubber Cable Version Comparison
| Item | VDE H07RN-F (Germany / EU) | UL Equivalent Rubber Cable (USA / Canada) | AS/NZS 5000.1 SAA Version (Australia / NZ) |
|---|---|---|---|
| Main Standard | VDE 0282, HD 22.4 | UL flexible rubber power cable | AS/NZS 5000.1 |
| Rated Voltage | 450/750V | 600V common | 450/750V |
| Conductor Marking | mm² metric | AWG gauge | mm² metric |
| Wiring Code | VDE 0100, IEC60364 | NFPA70 | AS/NZS 3000 |
| Representative Reference | LAPP H07RN-F | US portable rubber cord | AU site temporary power cable |
| Main Application | EU construction site, power tools, generator leads | North America portable equipment, extension cords | Australia & New Zealand temporary power, mining auxiliary power |
Important: Three versions are not fully interchangeable. North America site inspection requires UL listed rubber cable; Australian local approval needs SAA AS/NZS5000.1; EU tender projects prefer VDE H07RN-F, LAPP H07RN-F equivalent type. Always specify exact standard, core count and cross-section on purchase order.
Industrial Applications of H07RN-F Rubber Cable
European Construction & Portable Tools (VDE Version)
Typical Scenarios: Building site temporary power, electric drill, grinder, portable compressor, generator connection cable, LAPP H07RN-F wiring.
North America Portable Power Equipment (UL Equivalent Version)
Typical Scenarios: US & Canada heavy duty extension cords, portable pump, outdoor lighting, NFPA70 compliant mobile power cable.
Australia & New Zealand Site Power (SAA AS/NZS5000.1)
Typical Scenarios: Australian construction, farm mobile power, mining auxiliary temporary power, SAA site approval.
Generator & Water Pump Connection (All Versions)
Typical Scenarios: Diesel generator output cable, submersible surface pump, sewage pump mobile power lead.
Outdoor Stage & Event Lighting
Typical Scenarios: Outdoor performance lighting, temporary event power distribution, frequent dragging and moving.
Note: H07RN-F is a mobile flexible rubber cable for temporary use. It is not designed for permanent buried installation or fixed wiring without mechanical protection. Current Carrying Capacity must be checked before load matching.
H07RN-F Regional Version Selection Guide
Choosing proper certified H07RN-F rubber cable avoids local electrical inspection failure and overheating risk for export orders.
| Product | Main Merits | Typical Limitation | Suitable Application |
|---|---|---|---|
| VDE H07RN-F | EU widely recognized, complete Vde h07rn f rubber cable size range, LAPP H07RN-F equivalent, mature H07RN-F Datasheet | Not UL listed for US inspection | Germany, EU, Southeast Asia, Middle East construction & power tool export |
| UL Equivalent Rubber Cable | UL Listed, AWG marking, NFPA70 compliant | Higher certification cost | USA, Canada portable power OEM |
| SAA AS/NZS5000.1 Rubber Cable | SAA certified, meets AU electrical rules | Longer lead time for SAA audit | Australia, New Zealand temporary power projects |
| H07RN-F Cable 2.5mm 3 Core | Hot popular specification for power tools, balanced size and current | Medium load only | Portable power tools, small extension leads |
Material Selection Note: Visually similar rubber cables cannot substitute each other for export projects. Always specify certification standard (VDE / UL / SAA), core count and cross-section according to destination country electrical regulation.
Manufacturing & Installation Guidance
Conductor Production
Fine bare oxygen-free copper filaments, stranding into Class 5 flexible conductor; UL version produced to AWG construction, SAA version follows AS/NZS stranding requirement.
Insulation & Sheath Extrusion
EPR rubber insulation extruded on each conductor, color coded; rubber fillers fill the gaps to keep round structure. CR neoprene rubber outer sheath is extruded, vulcanized for weather and ozone resistance. Marking printed accordingly: metric marking for VDE/SAA, AWG marking for UL version. Continuous meter marking and model information printed along sheath surface.
On‑Site Installation Notes
Installation shall follow local wiring standard: VDE0100 (DE), NFPA70 (US), AS/NZS3000 (AU), IEC 60364.
Check H07RN-F Cable current Carrying Capacity before connecting loads, derate for high temperature and bundled laying.
Avoid dragging over sharp metal edges to prevent sheath damage; use cable protection when necessary.
Not suitable for permanent buried installation without conduit protection.
Keep away from high-temperature heat sources.
Standards and Material Compliance
| Standard / Designation | Application |
|---|---|
| VDE 0282 | German H07RN-F rubber cable standard |
| HD 22.4 | European harmonized rubber flexible cable specification |
| IEC 60245 | Rubber insulated cables standard |
| AS/NZS 5000.1 | Australian flexible rubber power cable standard for SAA certification |
| IEC 60228 Class 5 | Flexible conductor requirement |
| VDE 0100 | German electrical installation wiring rule |
| NFPA 70 | US national electrical code |
| AS/NZS 3000 | Australian wiring rules |
| IEC 60364 | International low voltage electrical installation rule |
| CE RoHS | EU environmental compliance |
| EN 10204 3.1 | Material inspection test report type |
Important Distinction: Cable standard defines electrical and mechanical performance; local installation code governs laying method, current derating and safety rules. Export purchase order must specify target market certification (VDE / UL / SAA), voltage rating and load requirement. You can request H07RN-F Datasheet for full technical data.
Inspection & Quality Assurance
Shaanxi Jinshenghong Cable Co., Ltd. supports project‑oriented inspection and documentation for international construction and portable power procurement. Inspection items are defined by product standard and buyer purchase order.
Conductor Resistance Test
Check copper conductor resistance conforming to VDE / UL / AS/NZS requirement.
High‑voltage Withstand Test
Routine AC voltage withstand test adjusted per regional standard for insulation integrity check.
Insulation Resistance Measurement
Verify insulation performance under rated temperature.
Dimensional Inspection
Check conductor cross‑section / AWG size, insulation thickness, sheath thickness and outer diameter, confirm Vde h07rn f rubber cable size compliance.
Current Carrying Capacity Test
Test and verify H07RN-F Cable current Carrying Capacity for load design.
Aging & Weather Resistance Test
Rubber heat aging test to confirm long-term outdoor service life.
Visual & Marking Inspection
Check sheath surface, core color coding, metric/AWG marking, continuous meter‑marking, batch traceability marking.
Third‑Party Witness Inspection
Can arrange third‑party witness inspection if contract required.
Material Test Certificates
EN10204‑3.1 factory test report available as contract agreed. Additional VDE, UL, SAA, CE RoHS documents and H07RN-F Datasheet need to be confirmed before order confirmation.
Packaging and International Shipping
H07RN-F rubber cable is heavy-duty flexible rubber power cable, requires proper export packing to prevent sheath scratch and rubber deformation during ocean / land transport.
| Product | Packaging Method |
|---|---|
| VDE / SAA Metric H07RN-F | Wooden drum, wrapped with moisture‑proof film, waterproof label with metric specs |
| UL Equivalent AWG Rubber Cable | Wooden drum + protective film, marking with AWG gauge |
| H07RN-F Cable 2.5mm 3 Core | Wooden drum or small coil packing for retail extension cord |
| Small‑order Sample | Moisture‑proof bag + carton box |
Packaging must keep batch identification labels intact, avoid mixing different batch goods. Shipping solution: sea freight, air freight according to customer logistics requirement.
Why Choose Shaanxi Jinshenghong Cable Co., Ltd.?
Multi-Standard Rubber Cable Sourcing Capability
Supply VDE H07RN-F, LAPP H07RN-F equivalent rubber cable, UL equivalent rubber cable, SAA AS/NZS5000.1 rubber cable, complete Vde h07rn f rubber cable size range for global construction and portable power buyers.
Specification‑oriented Quotation
Our quotation confirms target‑market certification (VDE / UL / SAA), core count, mm² or AWG size, packing, current carrying capacity and test‑document requirement.
Customized Requirement Support
Accept custom cut‑length, custom marking, custom core count and export‑packaging solution. We can provide H07RN-F Datasheet upon request.
Complete Quality Documentation
Provide factory test reports and assist for VDE, UL, SAA, CE RoHS, current carrying capacity test document check.
Global B2B Supply
Serve cable distributors, construction companies, power tool OEMs, generator manufacturers and equipment wholesalers for EU, US, Australia and worldwide markets.
Frequently Asked Questions About H07RN-F Rubber Cable
Q1. What is H07RN-F cable meaning?
H07RN-F is European harmonized heavy-duty rubber flexible cable. H=harmonized standard, 07=450/750V, R=rubber insulation, N=CR neoprene rubber sheath, F=fine flexible conductor. It is widely known as VDE H07RN-F rubber cable, LAPP H07RN-F equivalent type.
Q2. What is the difference between VDE H07RN-F, UL and SAA rubber cable?
VDE H07RN-F follows VDE 0282 / HD22.4, 450/750V metric size; UL rubber cable is for North America, marked by AWG; SAA AS/NZS5000.1 is Australia standard, each matches local electrical inspection rules.
Q3. What is H07RN-F Cable current Carrying Capacity?
Current Carrying Capacity depends on cross-section, ambient temperature and laying method. The popular H07RN-F Cable 2.5mm 3 Core has fixed rated current data; full values can be found in H07RN-F Datasheet.
Q4. What is the most popular Vde h07rn f rubber cable size?
H07RN-F Cable 2.5mm 3 Core is the best-selling size, widely used for portable power tools and heavy extension cords.
Q5. Can H07RN-F cable be used outdoors?
Yes, CR neoprene sheath provides excellent ozone and weather resistance for outdoor temporary use, but it is not for permanent buried installation without conduit.
Q6. What temperature range for H07RN-F?
Operating temperature range: -25℃ ~ +60℃.
Q7. Is H07RN-F the same as LAPP H07RN-F?
Our VDE H07RN-F is fully compatible and equivalent to LAPP H07RN-F, same standard VDE 0282, HD22.4.
Q8. What information is needed for Vde h07rn f rubber cable price quotation?
Please specify certification standard (VDE / UL / SAA), core count, cross-section or AWG, quantity and destination port. You can also ask for H07RN-F Datasheet.
Q9. Is H07RN-F suitable for submersible pump?
Standard H07RN-F is not submersible grade; it can only be used for surface pump connection, not long-term underwater soaking.
Q10. What is the rated voltage of H07RN-F?
450/750V.
contact us
Contact us today to know more deatils about the VDE H07RN-F rubber cable;
Hot Tags: vde h07rn-f rubber cable, China vde h07rn-f rubber cable manufacturers, suppliers, cost effective rubber cable, copper conductor rubber cable, rubber cable for sale, rubber cable for office wiring, H07RN F Industrial Cable, get rubber cable