TPS Flat Cable Electrical Wiring | AS/NZS 5000.2 SAA RCM Approved Twin & Earth Building Wire

AS/NZS 5000.2 TPS Flat Cable | 450/750V V‑90 Insulation | SAA RCM Australian House Wiring Cable
Shaanxi Jinshenghong Cable Co., Ltd. supplies TPS Flat Cable (Twin and Earth Cable) for international residential building, commercial construction, renovation project procurement. TPS is the Australian‑New‑Zealand designation for PVC flat fixed wiring cable, widely used for lighting & power circuit installation.
Also known as Twin & Earth flat cable, TPS flat wiring adopts V‑90 PVC insulation and 3V‑90 outer sheath, features easy‑tear flat sheath for fast field termination. For global market equivalents: Chinese BVVB, German VAF‑G, American NM‑B Romex non‑metallic sheathed cable.
We support B2B project sourcing, custom cross‑section, custom cut‑length, full set test certificates, different market certification requirement and customized export packaging.
Customers can request quotations for AS/NZS 5000.2 TPS flat cable, GB/T5023 BVVB flat wire, VDE VAF‑G flat cable, UL NM‑B building wire according to project specification.
What Is TPS Flat Cable Electrical Wiring?
TPS Flat Cable (Thermoplastic Sheathed Flat Cable, also called Twin and Earth Cable) is flat‑shaped PVC insulated PVC sheathed fixed building wiring cable mainly popular in Australia & New‑Zealand market, rated at 450/750V with 90℃ temperature grade(V‑90 insulation,3V‑90 sheath).
Conductor is high‑purity annealed copper, available in solid or stranded class‑2 conductor structure. Common core configuration: 2 core, 2 core plus protective earth (2C+E), 3 core, 3 core plus earth (3C+E). The flat profile makes it convenient for laying inside wall cavity, conduit, under plaster and ductwork for domestic & commercial power‑lighting circuits.
TPS flat cable features easy‑tear outer sheath design to speed up stripping and termination on construction site. Different regional standards define equivalent flat building wires for China, Germany/Europe and North‑America markets.
This cable is intended for fixed wiring installation, not suitable for frequent flexible movement applications. Typical environment: dry indoor, protected conduit laying, not for direct bury exposed to heavy mechanical damage unless additional mechanical protection is applied.
Key Material Advantages
| Property | Engineering Benefit |
|---|---|
| V‑90 /3V‑90 PVC Compound | 90℃ high temperature resistance for long‑term building wiring service |
| Easy‑tear Flat Outer Sheath | Fast stripping, improves electrician installation efficiency |
| High‑purity Annealed Copper Conductor | Low conductor resistance, stable power transmission performance |
| Multiple Core Configurations | 2C /2C+E /3C /3C+E for single‑phase & multi‑phase wiring |
| Multi‑standard Versions | Available for AU‑NZ(AS/NZS), CN(GB), DE(VDE), US(UL) market |
| Flame Retardant Performance | Complies with IEC 60332‑1 non‑flame‑propagation requirement |
| Flat Compact Profile | Saves installation space in wall cavities & conduits |
| Full Traceability | Batch marking, meter marking along cable outer surface |
Engineering Note: Installation shall strictly comply with local wiring codes: AS/NZS3000 for Australia‑New‑Zealand, GB 50217 for China, IEC 60364 for EU, NEC code for USA. Environment temperature, installation method, derating factor must be considered for current‑carrying capacity.
|
Size(mm) |
No./Dia.of Conductor(mm) |
No./dia. of Earth core(mm) |
Max outer diameter(mm) |
|
2X1.5 |
2X7/0.52 |
/ |
4.9X7.8 |
|
2X2.5 |
2X7/0.68 |
/ |
5.6X9.3 |
|
2X4.0 |
2X7/0.83 |
/ |
6.2X10.3 |
|
2X6.0 |
2X7/1.04 |
/ |
6.8X11.6 |
|
2X1.0+2X1.0 |
2X7/0.43 |
7/0.43 |
4.2X6.8 |
|
2X1.5+1X1.5 |
2X7/0.52 |
7/0.52 |
4.6X10.2 |
|
2X2.5+1X1.5 |
2X7/0.68 |
7/0.52 |
5.5X12.8 |
|
2X4.0+1X1.5 |
2X7/0.83 |
7/0.68 |
6.2X14.1 |
|
2X6.0+1X1.5 |
2X7/1.04 |
7/0.68 |
6.8X15.3 |
|
2X10.0+1X4.0 |
2X7/1.35 |
7/0.83 |
7.8X17.7 |
|
2X16.0+1X6.0 |
2X7/1.71 |
7/1.04 |
9.4X21.8 |
TPS Flat Cable Product Specifications
Below data is procurement reference for TPS flat cable and its equivalent regional flat wiring products. Real available cross‑sections depend on production capacity, MOQ and certification scope.
| Product Form | Cross‑section Reference | Supply Condition |
|---|---|---|
| AU‑NZ TPS Flat Cable | 1.0mm²‑16mm²; 2C /2C+E /3C /3C+E | SAA/RCM certified, white/grey/blue sheath, factory reel or custom cut length |
| Chinese BVVB Flat Cable | 1.0mm²‑16mm² | CCC certified, solid copper, PVC flat sheath |
| German VAF‑G Flat Cable | 1.5mm²‑10mm² | VDE certified, 450/750V flat twin‑and‑earth |
| US NM‑B Romex Cable | 14AWG‑6AWG | UL719 listed non‑metallic sheathed building wire |
| Custom Flat Wiring | Special core count / special cross‑section | Subject to technical feasibility & minimum order |
| Packing Form | 100m/roll, 200m/roll, drum packing | Factory standard packing or customized export packing |
Cross‑section and core configurations listed are typical industry references, not guaranteed stock. Final availability and certification scope must be confirmed during quotation.
Common Supply Requirements
| Parameter | Available Procurement Options |
|---|---|
| Product Grade | TPS Flat Cable / BVVB / VAF‑G / NM‑B |
| Primary Standard | AS/NZS5000.2; GB/T5023‑2008; VDE0281; UL719 |
| Local Wiring Code | AS/NZS3000; NEC; IEC60364, as specified |
| Rated Voltage | 450/750V main rating |
| Temperature Class | V‑90 / 3V‑90 for TPS; 70℃ or 90℃ for other regional variants |
| Conductor Material | Annealed copper (solid / stranded class‑2) |
| Core Configuration | 2C,2C+E,3C,3C+E |
| Sheath Color | White, grey, blue as per market habit |
| Length | Standard reel length or custom cut‑to‑length |
| Dimensional Tolerance | Follow corresponding product standard or buyer drawing |
| Product Marking | Continuous meter marking, standard mark, batch number traceability |
| Inspection Certificate | EN10204‑3.1, test report, certification document upon agreement |
For critical building projects, buyers shall specify installation code, certification requirement and core configuration before placing order.
TPS Flat Cable Construction Parameters
TPS flat cable is thermoplastic sheathed flat building wire, V‑90 PVC for core insulation and 3V‑90 PVC for outer sheath for Australian standard version.
| Component | Description |
|---|---|
| Conductor | High‑purity annealed copper, solid or stranded class‑2 |
| Insulation | V‑90 PVC compound, color‑coded cores (Red / Black / White / Green‑Yellow earth) |
| Outer Sheath | 3V‑90 easy‑tear flat PVC sheath |
| Rated Voltage | U0/U:450/750V |
| Max Operating Temperature | 90℃ |
| Test Voltage | 2500V AC for 5 minutes routine withstand test |
Construction compliance shall refer to corresponding edition of AS/NZS5000.2, GB/T5023‑2008, VDE0281 or UL719, based on buyer market requirement.
Electrical & Physical Propertie
Electrical parameters vary with conductor cross‑section, conductor structure and product standard. Below are representative reference values.
| Property | Typical Reference Value |
|---|---|
| Rated Voltage | 450/750V |
| Maximum Conductor Operating Temperature | 90℃ (TPS V‑90 version) |
| Minimum Installation Ambient Temperature | ‑15℃ |
| Minimum Bending Radius | ≥6 × overall cable dimension |
| Flame Retardant Characteristic | IEC60332‑1 flame non‑propagation |
| Conductor Resistance | Comply with IEC 60227 series requirement |
Values for preliminary engineering reference. Actual current‑carrying capacity calculation must follow local wiring regulation, installation method, ambient temperature and cable grouping factor.
TPS Flat Cable Equivalent Standards Comparison
TPS is exclusive Australian‑New‑Zealand naming; other geographic markets adopt separate model designation for functionally similar flat fixed wiring cable.
| Item | AU‑NZ TPS Flat Cable | CN BVVB | DE VAF‑G | US NM‑B(Romex) |
|---|---|---|---|---|
| Main Standard | AS/NZS5000.2 | GB/T5023‑2008 | VDE0281 | UL719 |
| Certification | SAA / RCM | CCC | VDE | UL Listed |
| Rated Voltage | 450/750V | 450/750V | 450/750V | 600V |
| Temperature Grade | 90℃(V‑90/3V‑90) | 70℃ | 70℃ | 90℃ |
| Core Options | 2C,2C+E,3C,3C+E | 2C,2C+E,3C,3C+E | 2C+E,3C+E | 2C+E,3C+E |
| Main Application | AU‑NZ domestic & commercial fixed wiring | China building fixed wiring | European domestic fixed wiring | USA residential building wiring |
Important: TPS flat cable, BVVB, VAF‑G and NM‑B are functional equivalents but NOT fully interchangeable. When exporting to target market, you must specify exact standard and certification rather than only cable appearance.
Industrial Applications of TPS Flat Cable Electrical Wiring
TPS flat cable series is designed for fixed indoor building wiring for power & lighting circuits.
Residential Domestic Installation
Typical Scenarios: House wall wiring, power socket circuit, lighting circuit, renovation rewiring. TPS flat cable's flat shape is well‑suited for wall‑cavity and conduit installation for AU‑NZ residential projects.
Commercial Building Projects
Typical Scenarios: Office, retail shop, hotel fixed wiring for lighting, power distribution inside protected conduit or wall cavity.
Equivalent‑Model Regional Projects
BVVB for Chinese market: Apartment, commercial complex fixed wiring; VAF‑G for European market: Germany and EU domestic building wiring; NM‑B Romex for North‑America: USA residential construction fixed non‑metallic building wiring.
Retrofitting & Renovation Works
Typical Scenarios: Old building rewiring, renovation projects where easy‑tear sheath helps fast termination for large‑volume site work.
Note: TPS flat cable is for protected fixed installation, NOT for direct underground burial without extra mechanical protection, NOT for portable flexible cord applications.
TPS Flat Cable vs Equivalent Flat Building Wires
Choosing proper regional flat cable model avoids certification non‑compliance risk for export orders.
| Product | Main Merits | Typical Limitation | Suitable Market |
|---|---|---|---|
| TPS Flat Cable(AS/NZS5000.2) | V‑90 high temperature grade, easy‑tear sheath, SAA/RCM compliance | TPS naming only recognized in Australia‑New‑Zealand | Australia, New‑Zealand |
| BVVB Flat Cable (GB/T5023‑2008) | Cost‑effective, CCC certified | 70℃ base grade normally, not directly accepted for AU market without SAA | China domestic |
| VAF‑G(VDE0281) | VDE European certification | 70℃ temperature rating | Germany & EU countries |
| NM‑B Romex(UL719) | UL listed American standard | Unique US construction structure, higher cost | United States |
Material Selection Note: Visual similar flat cables cannot substitute each other for export projects. Always specify product standard, certification and temperature rating on purchase order according to destination country wiring regulation.
Manufacturing & Installation Guidance
Conductor Production
TPS flat cable uses high‑quality annealed copper conductor, solid or stranded class‑2 structure according to specification. Copper raw material purity controls conductor resistance performance.
Extrusion & Flat Sheath Forming
Insulation(V‑90 PVC) and outer sheath(3V‑90 PVC) are extruded in flat profile. Special easy‑tear notch structure is embedded in outer sheath for convenient stripping at construction site. Meter‑marking and standard information are continuously printed along sheath surface.
On‑Site Installation Notes
Installation shall follow local wiring code: AS/NZS3000(AU‑NZ), NEC(US), IEC60364(EU), GB50217(CN).
Minimum bending radius shall not be less than 6 times cable overall dimension to avoid sheath crack.
Avoid laying where subject to heavy mechanical impact without additional protective conduit.
Termination operation: take advantage of easy‑tear sheath; do not damage core insulation during stripping.
Standards and Material Compliance
International buyers need to distinguish product‑performance standard, market access certification and installation wiring codes.
| Standard / Designation | Application |
|---|---|
| AS/NZS 5000.2 | Primary product standard for AU‑NZ TPS flat cable |
| AS/NZS 3000 | Australian‑New‑Zealand wiring installation rule |
| GB/T 5023‑2008 | Chinese BVVB flat cable product standard |
| VDE 0281 | German VAF‑G flat building wire standard |
| UL 719 | US NM‑B Romex non‑metallic sheathed cable |
| IEC 60227 | General low‑voltage PVC insulated cable base standard |
| IEC 60332‑1 | Flame retardant test requirement |
| EN 10204 3.1 | Material inspection test report type |
| Local Market Certification | SAA/RCM, CCC, VDE, UL Listed |
Important Distinction: Product performance standard (e.g. AS/NZS5000.2) defines cable construction & electrical performance; installation code (e.g. AS/NZS3000) governs site laying rules. Export purchase order must specify both product standard and required market‑access certification.
Inspection & Quality Assurance
Shaanxi Jinshenghong Cable Co., Ltd. supports project‑oriented inspection and documentation for international building‑wire procurement. Inspection items are defined by product standard and buyer purchase order.
Conductor Resistance Test
Check copper conductor resistance conforming to standard requirement.
High‑voltage Withstand Test
Routine AC voltage withstand test for insulation integrity check.
Insulation Resistance Measurement
Verify insulation electrical performance.
Dimensional Inspection
Check conductor cross‑section, insulation thickness, sheath thickness, flat outer dimension.
Visual & Marking Inspection
Check sheath surface, core color‑coding, continuous meter‑marking, standard marking, batch traceability marking.
Third‑Party Witness Inspection
Can arrange third‑party witness inspection if contract required.
Material Test Certificates
EN10204‑3.1 factory test report available as contract agreed. Additional certification documents (SAA/RCM/CCC/VDE/UL) need to be confirmed before order confirmation.
Why Choose Shaanxi Jinshenghong Cable Co., Ltd.?
Building‑wire Sourcing Capability
Supply TPS flat cable and regional equivalent flat building wires for global construction‑project buyers.
Specification‑oriented Quotation
Our quotation confirms target‑market standard, certification, cross‑section, core configuration, packing and test‑document requirement.
Customized Requirement Support
Accept custom cut‑length, special packing, special marking according buyer drawing & technical requirement.
Complete Quality Documentation
Provide factory test reports and assist for certification‑related document check.
Global B2B Supply
Serve cable distributors, electrical wholesalers, building contractors, electrical installation companies worldwide.
FAQ
Q1. What is TPS Flat Cable?
TPS Flat Cable, also known as Twin and Earth Cable, is Australia‑New‑Zealand specific V‑90 PVC insulated flat thermoplastic‑sheathed fixed building wiring cable, rated 450/750V, widely used for domestic and commercial lighting & power circuits.
Q2. Are TPS Cable and BVVB cable same?
Not identical. BVVB is Chinese GB/T5023‑2008 flat cable, functionally similar flat‑sheathed building wire, but material formula, temperature grade and certification system differ. BVVB cannot replace TPS for Australian import without SAA/RCM certification.
Q3. What is primary standard for TPS flat cable?
AS/NZS5000.2 is core product standard for TPS flat cable, installation follows AS/NZS3000 wiring rule.
Q4. What does 2C+E mean for TPS cable?
2‑core plus protective earth conductor, typical configuration for Australian domestic power socket wiring.
Q5. Can TPS flat cable be buried directly underground?
Not recommended without extra mechanical protective conduit. TPS is for protected fixed installation, outer sheath is not designed for direct soil burial.
Q6. What core configurations are available for TPS flat cable?
Common options: 2C, 2C+E, 3C, 3C+E, cross‑section range 1.0mm²‑16mm².
Q7. What is V‑90 and 3V‑90 marking on TPS cable?
V‑90 stands for 90℃ rated PVC core insulation; 3V‑90 stands for 90℃ rated PVC outer sheath compound for Australian TPS cable.
Q8. Can you supply equivalent flat cable for Germany / USA market?
Yes: VAF‑G for VDE German market; NM‑B(Romex) for UL US market; BVVB for Chinese CCC market. Please specify destination country when sending inquiry.
Q9. Do you accept custom cut‑length TPS flat cable?
Custom cut‑length can be considered subject to MOQ and production schedule, buyers need to specify exact length requirement for quotation.
Q10. What information is needed for TPS flat cable quotation?
Please provide target‑market standard, certification requirement, core configuration, cross‑section area, total quantity, packing requirement, destination port and special document requirements.
Conclusion
Contact us today to learn more information about the TPS flat cable electrical wiring;
Phone: +86-18802926539
Envelope: cable3@sxjshsm.com
Whatsapp: +86-18802926539
Skype: +86-18802926539
Wechat: 18802926539
Hot Tags: tps flat cable electrical wiring, China tps flat cable electrical wiring manufacturers, suppliers, corrosion resistant flat cable, flat cable for inductors, flat cable for memory cards readers, flat cable for telecommunications accessories, flat cable for network cards, flat cable for usb connection