Wire And Cable For Electronic Computers, Electrical Instrument Equipment And Devices

Wire And Cable For Electronic Computers, Electrical Instrument Equipment And Devices
Details:
Minimum ambient temperature: The minimum ambient temperature for conventional computer cable laying is 0 ℃. Maximum working temperature: The maximum allowable working temperature for cables in the long term varies depending on the material. Insulation resistance: After a stable charge of 1 minute with a DC 500V voltage test at 20 ℃, there should be no open circuit between the twisted pair shields and between the twisted pair shields and the total shield. The cable core to core and between the core and the shield or other metal layers should withstand 50Hz, with an AC voltage of 2000V/1 minute or 1500V/5 minutes without breakdown. Bending radius: For unarmored structures, it should not be less than 6 times the outer diameter of the cable, and for structures with armor or copper tape shielding, it should not be less than 12 times the outer diameter of the cable.
Send Inquiry
Chat Now
Download
Description
Technical Parameters

Shaanxi Jinshenghong Cable Co., Ltd. is one of the most reliable manufacturers and suppliers of wire and cable for electronic computers, electrical instrument equipment and devices in China. Please feel free to wholesale high quality customized products at low price from our factory. For free sample and cheap products, contact us now.

 

Products Description
-2
 

The wires and cables used in electronic computers and electrical instrument equipment are key components used in electronic computers and electrical instrument equipment. They are responsible for transmitting electrical energy and signals to ensure the normal operation of the equipment.
The composition materials of computer cables and instrument equipment wires and cables may vary due to special requirements such as usage temperature and working environment, but usually include conductors, insulation layers, shielding layers, sheath layers, etc.
Computer cable: suitable for electronic computers and automation instruments with high anti-interference requirements for rated voltage of 500V and below. This type of cable can use insulation materials such as polyethylene, polyvinyl chloride, cross-linked polyethylene, fluoroplastics, silicone rubber, etc. according to different environments and equipment usage requirements. Instrument equipment wires and cables: used in electrical instrument equipment installations, there are multiple models and specifications to choose from according to the specific needs of the equipment.
In order to reduce mutual crosstalk and external interference between circuits, cables need to adopt shielding structures. Shielding materials include tinned or non tinned copper wire, copper tape, copper-plastic composite tape, aluminum-plastic composite tape, etc. The shielding requirements are adopted according to different occasions: partial shielding (only for twisted pairs, each twisted pair has shielding), total shielding (the cable only has one layer of total shielding after the cable core is assembled), partial shielding+total shielding (including the above two structures).

Application scope

This product is suitable for use as a connecting wire for electrical appliances, instruments, and computers in distribution devices with a rated voltage of 350/500V

 

Production scope
Model Nominal cross-section Number of core pairs

DJVVR, DJVVRP, DJVVP2R

DJVVP3R, DJVPVRP, DJVP3VP3R

0.5, 0.75, 1, 1.5 1~40

DJVV, DJVVP, DJVVP2, DJVVP3, DJYVP

DJYVP2, DJYVP3, DJVPVP, DJVP2VP2

DJVP3VP3, DJYPV, DJYP2V, DJYP3V, DJYPVP

DJYP2YP2, DJYP3VP3, DJYPVVR, DJYP2VR

DJYP3VR, DJYPVPR, DJYP2VP2R, DJYP3VP3R

0.5, 0.75, 1, 1.5 1~40

DJVVP22, DJVVP2-22, DJVVP3-22, DJYVP22

DJYVP3-22, DJVPVP22, DJVP2VP2-22, DJVP3VP3-22

DJYPV22, DJYP2V22, DJYP3V22, DJYPVP22

DJYPVP2-22, DJYP3VP3-22

0.5, 0.75, 1, 1.5 1~40

 

Products inventory

-3

 

 

Product Process Diagram

-4

 

 

FAQ

 

Q1: What is the rated voltage of computer cables?
A1: The rated voltage of computer cables is 300/500V.


Q2: What are the models of computer cables?
A2: The models of computer cables mainly include DJVPVRP DJYVP, DJYPV, DJYPVP, etc.


Q3: What is the difference between computer cables and control cables?
A3: The main difference between computer cables and control cables lies in their purpose, structure, and performance. Computer cables are mainly used for connecting electronic computers and automation instruments, with good shielding performance; And control cables are mainly used for controlling and protecting circuits in industrial and mining enterprises, energy and transportation departments, and other occasions. Structurally, computer cables have slightly weaker mechanical strength and are suitable for use in indoor environments; And the control cable has high mechanical strength, making it more suitable for laying in outdoor or even underground environments.


Q4: What are the requirements for the usage environment of computer cables?
A4: When using computer cables, the ambient temperature should not be lower than -40 ℃ for fixed laying and -15 ℃ for non fixed laying. In addition, the insulation resistance of the cable should not be less than 2500M Ω· Km after stable charging with a DC 500V voltage test at 20 ℃ for 1 minute.

 

contact us
 

 

tel.png

tel: +86-18092115246

envelope.png

Envelope: Bella@sxjshsm.com

address.png

Whatsapp: +86-18092115246

fax.png

Wechat: +86-18092115246

 

Hot Tags: wire and cable for electronic computers, electrical instrument equipment and devices, China wire and cable for electronic computers, electrical instrument equipment and devices manufacturers, suppliers, H03VV F RVV Soft Electric Cable, 450V 750V Flexible Rubber Welding Cable, Corrosion Resistant High Voltage Teflon Cable, UL 1007 Tinned Copper Single Core Wire, Flame Retardant Aluminum Power Cable, Self Locking Armored Aluminum Alloy Cable